UHP-Black-LED-520
Introduction
| The Fiber Coupled Ultra High Power
LED provides almost x10 increase of
power in comparison with similar High
Power LED devices. The Ultra High
Brightness LED is an effective
replacement of lasers and lamps in
many power demanding applications,
such as fluorescence microscopy,
machine vision, chemical reaction
activation and numerous others. The
LED head provides more than 100 mW
of CW power at fiber output. The LED
driver supports CW or pulsed
operation. |
 |
Features
- Ultra High Power fiber coupled LED
- Speckle free
- TTL external modulation
- Excellent for fluorescence excitation
- LED spectrum can be narrowed by optional band pass filter installed inside the head.
- Reciprocal SMA, FC or ST fiber connection
- Precisely adjustable power
- Long life (no lamp or laser tube replacement required)
- Rapid warm up time
Applications
- Machine Vision
- Fluorescence microscopy and imaging (Alexa Fluor 514, Cy3, SNAFL®, SNARF®,
FM 4-64)
- Fluorescence spectroscopy
- Photo activation (PA)
- Fluorescence recovery after photo bleach (FRAP)
- Bio analysis
- Component testing
Optical Specifications
| Wavelength |
nm |
520 |
| Wavelength range |
nm |
±5 |
| Spectrum half width |
nm |
36 |
| Polarization |
|
Random |
| Optical output connector |
|
SMA, FC, ST |
Power output from fiber:
UHP-Black-LED power output is limited by the reciprocal fiber characteristics. Larger
core and higher NA will increase maximum power output, and vice versa.
The table below shows a few examples of the CW output power at different fibers:
| Fiber brand | Fiber type*¹ | NA | Fiber Core Diameter | Output Power Typical*² |
Toray PGR-FB1500 or
Mitsubishi Rayon SH6001 |
POF |
0.5 |
1500 µm |
>100 mW |
Toray PGR-FB1000 or
Mitsubishi Rayon SH4001 |
POF | 0.5 | 1000 µm |
>50 mW |
*1: Fiber length ~ 1 m; POF - Polymer Optical Fiber
*2:The measurement done by Ophir Nova II power meter equipped with PD300-UV head. The
wavelength is set at 520 nm. The values are for non filtered UHP-LED.
Benchtop LED Current Controller Specifications
Features
- Constant current or chopping modes
- Precise LED current setting by 10 turn dial
- TTL external trigger input
- Compact and robust enclosure
| Digital modulation input |
|
TTL |
| Connector for TTL input |
|
BNC |
| Digital modulation frequency |
Hz |
DC-30000 |
| Rise / Fall time (10% - 90%) |
μs |
2 |
| ON/OFF extinction |
|
>10&sup6; : 1 |
| Input Voltage |
V |
12 |
| Max Input current |
A |
5.5 |
| Power Adaptor Input |
|
100-240 VAC, 50-60Hz, 1.5A |
General Specifications
| Operation temperature range |
°C |
10-35 |
| Storage temperature range |
°C |
-10-55 |
Operating relative humidity (Non
condensing) |
% |
<90 |
| Head dimensions |
|
See drawing below |
| Head weight |
g |
500 |
| Controller dimensions (LxWxH) |
|
220mm x 165mm x 51.5mm |
| Controller weight |
g |
700 |
Power adaptor dimensions
(LxWxH) |
|
146mm x 76mm x 44mm |
| Power adaptor weight |
g |
600 |
| Fan noise |
dBA |
38 |
Performance
 |
 |
| UHP-Black-LED-520 spectrum |
UHP-Black-LED-520 Stability |
Optional Accessories
Fiber patch cords:
Various fiber optic patch cords are available for use with the 3-LED or 5-LED products.
Most popular patch cords are 1000 / 1500 / 2000 micron core diameter Polymer Optical Fibers (POF)
terminated by optical SMA connectors on both sides. Prizmatix can provide Stainless Steel tube at one end of
the patch cord instead of the SMA connector. This configuration is more convenient in some applications.
See more info...
Collimator:
The output from optical fiber is divergent according to fiber NA. In order to reduce the
divergence angle a collimator module can be used. Prizmatix collimator was especially designed to fit thick
core high NA Polymer Optical Fibers.
See more info...
Fiber Bundles:
To combine outputs of multiple LEDs a Y-shaped fiber bundle with two or more input
branches can be used. Prizmatix can help to configure and build custom fiber bundles for specific applications.
See more info...
Special Bundles:
For spectroscopy application special fiber optic bundles are very important. Special care
must be addressed to eliminate possible cross link between the excitation and the collection fibers.
See more info...
Mechanical Drawings
|